Boost Your Productivity!Translate documents (Ms-Word, Ms-Excel, ...) faster and better thanks to artificial intelligence!
https://pro.wordscope.com
https://blog. wordscope .com
ACC
Arterial pressure control
Arterial pressure regulation
Auto-pressurization controller
Automatic chroma control
Automatic chrominance control
Automatic color gain control
Automatic colour gain control
Automatic pressure control
Automatic pressure control selector
Automatic pressurization controller
Automatic saturation control
Blood pressure control
Blood pressure regulation
Cabin pressure control valve
Direct reading automatic pressure controller
Pressure control forward discharge valve
Pressure control valve
Pressure controller
Pressure regulating valve
Pressure regulator

Translation of "Automatic pressure control " (English → French) :

TERMINOLOGY
see also In-Context Translations below
automatic pressure control selector

sélecteur de régulation


automatic pressure control

régulation automatique de pression


automatic pressure control

régulation automatique de pression


auto-pressurization controller [ automatic pressurization controller ]

régulateur de pressurisation automatique


direct reading automatic pressure controller

contrôleur de pression automatique à lecture directe


automatic chroma control | automatic chrominance control | automatic color gain control | automatic colour gain control | automatic saturation control | ACC [Abbr.]

commande automatique de chrominance | CAC [Abbr.]


cabin pressure control valve | pressure control forward discharge valve | pressure controller

régulateur de pressurisation de la cabine


blood pressure control | arterial pressure control | blood pressure regulation | arterial pressure regulation

régulation de la pression artérielle


pressure regulator | pressure controller | pressure control valve | pressure regulating valve

régulateur de pression


Automatic-aperture-control accelerator system collimator

collimateur de système accélérateur à commande d’ouverture automatique
IN-CONTEXT TRANSLATIONS
This device shall be so designed and constructed that the pressure in the connecting lines is positively restored to the rest position not later than the control (e.g. push button) of this device is automatically released (e.g. valve returns automatically into the normal operation position).

Ce dispositif doit être conçu et construit de telle sorte que la pression dans les conduites de liaison revienne positivement à la position de repos dès que la commande (un bouton-poussoir, par exemple) du dispositif est automatiquement relâchée (par exemple, la soupape revient automatiquement à sa position de fonctionnement normal).


In the case of towed vehicles equipped with an electric control line and electrically connected to a tractor with an electric control line the automatic braking action specified in point 2.2.1.17.2.2 of Annex I may be suppressed as long as the pressure in the compressed air reservoirs of the towed vehicle is sufficient to ensure the braking performance specified in point 3.2.3 of Annex II.

Dans le cas de véhicules tractés équipés d'une ligne de commande électrique et raccordés électriquement à un tracteur équipé lui aussi d'une ligne de commande électrique, l'action de freinage automatique visée au point 2.2.1.17.2.2 de l'annexe I peut être supprimée, à condition que la pression dans les réservoirs d'air comprimé du véhicule tracté soit suffisante pour obtenir l'efficacité de freinage définie au point 3.2.3 de l'annexe II.


(4) In every Class A ship over 22.9 m in length, at least one of the power fire pumps shall be fitted with an automatic control whereby full pressure will be maintained on the fire mains at all times while passengers are on board, but during conditions that may lead to freezing of sections of the pipelines, pressure need not be maintained on these sections; a pressure gauge shall be fitted on the fire main.

(4) Sur tout navire de la classe A, d’une longueur de plus de 22,9 m, au moins l’une des pompes d’incendie mécaniques aura une commande automatique permettant de maintenir en tout temps la pression dans les collecteurs alors que les passagers seront à bord, mais si les conditions peuvent provoquer le gel de certains tronçons des conduites, il ne sera pas nécessaire de maintenir ces tronçons sous pression; un manomètre sera install ...[+++]


(4) In every Class B ship over 22.9 m in length carrying more than 12 passengers, at least one of the power fire pumps shall be fitted with an automatic control whereby full pressure will be maintained on the fire mains at all times while passengers are on board excepting that where piping is liable to frost damage such piping may be maintained in a drained condition provided the shut-off valve and drainage cocks are located in a readily accessible location with a pressure gauge being installed on the drainable section of the piping i ...[+++]

(4) Sur tout navire de la classe B long de plus de 22,9 m et transportant plus de 12 passagers, au moins l’une des pompes d’incendie mécaniques aura une commande automatique permettant de maintenir en tout temps la pression dans les collecteurs pendant que des passagers seront à bord, mais si le gel risque d’endommager certains tronçons des conduites, ces tronçons peuvent être vidangés et demeurer dans cet état, à condition que la soupape d’ar ...[+++]


For more results, go to https://pro.wordscope.com to translate your documents with Wordscope Pro!
(e) in the case of ships required to be fitted with sprinkler systems under the Hull Construction Regulations, full particulars of the proposed installation showing pump capacities and types, means for bringing pumps automatically into action, connections to pressure tank and dry valve, sea cocks, control valves, pressure gauges, alarm switches, connections to ship’s fire pump, piping systems and location of sprinkler heads.

e) dans le cas des navires tenus d’être munis de systèmes d’extinction par pulvérisation d’eau en vertu du Règlement sur la construction des coques, tous les détails de l’installation, montrant le débit des pompes et leur type, les moyens de mettre les pompes automatiquement en marche, les raccordements au réservoir sous pression et à la soupape du type sec, les robinets de prise d’eau à la mer, les soupapes de manoeuvre, les manom ...[+++]


and in every case the push button control for the motor shall return automatically to the “off” position as soon as the pressure is released.

et dans tous les cas, le bouton-poussoir de commande du moteur devra automatiquement revenir à la position «arrêt» dès qu’on cessera de le presser.


(3) An excess flow valve or other automatic device as prescribed in subsection (1) is not required for withdrawal connections of tanks with a water capacity of 1,500 Imperial gallons or less if the connection is protected by a controlling orifice not exceeding 5/16 inch diameter on vapour withdrawal and not exceeding 1/8 inch diameter on liquid withdrawal, a manually operated shut-off valve and pressure-reducing regulator, all of which are assembled to the connection as prescribed ...[+++]

(3) Les soupapes d’excès de débit ou autres dispositifs automatiques prescrits au paragraphe (1) ne sont pas requis dans le cas des raccords d’extraction des réservoirs dont la capacité en eau est de 1 500 gallons impériaux ou moins, si le raccord est protégé par un orifice de contrôle dont le diamètre n’excède pas 5/16 de pouce pour l’extraction de gaz ni 1/8 de pouce pour l’extraction de liquide, par une soupape d’arrêt à commande manuelle et par un régulateur manodétendeur, tous ces dispositifs étant montés sur le raccordement comme il est prescrit à l’article 2.2(d), division II de l’édition ...[+++]


(a) instruments and apparatus for automatically controlling the flow, level, pressure or other variables of liquids or gases, or for automatically controlling temperature, whether or not their operation depends on an electrical phenomenon which varies according to the factor to be automatically controlled; and

a) les instruments et appareils pour la régulation des fluides gazeux ou liquides, ou pour le contrôle automatique des températures, même si leur fonctionnement a son principe dans un phénomène électrique variable avec le facteur recherché;


- under heading No 90.24, instruments and apparatus for measuring, checking or automatically controlling the flow, depth, pressure or other variables of liquids or gases, or for automatically controlling temperature, (for example, pressure gauges, thermostats, level gauges, flow meters, heat meters, automatic oven-draught regulators), not being articles falling within heading No 90.14;

- à la position 90.24, les appareils et instruments pour la mesure, le contrôle ou la régulation des fluides gazeux ou liquides, ou pour le contrôle automatique des températures, tels que manomètres, thermostats, indicateurs de niveau, régulateurs de tirage, débitmètres, compteurs de chaleur, à l'exclusion des appareils et instruments du nº 90.14;


6. Heading No 90.32 applies only to: (a) Instruments and apparatus for automatically controlling the flow, level, pressure or other variables of liquids or gases, or for automatically controlling temperature, whether or not their operation depends on an electrical phenomenon which varies according to the factor to be automatically controlled ; and

6. Le no 90.32 comprend uniquement: a) les instruments et appareils pour la régulation des fluides gazeux ou liquides, ou pour le contrôle automatique des températures, même si leur fonctionnement a son principe dans un phénomène électrique variable avec le facteur recherché;


w