Boost Your Productivity!Translate documents (Ms-Word, Ms-Excel, ...) faster and better thanks to artificial intelligence!
https://pro.wordscope.com
https://blog. wordscope .com
Coal fire gas turbine
Directly fired gas turbine
Fuel-fired gas turbine
Oil-fired gas turbine locomotive
Pulverised coal fired gas turbine

Translation of "Fuel-fired gas turbine " (English → French) :

TERMINOLOGY
see also In-Context Translations below
fuel-fired gas turbine

turbine à gaz alimentée par carburant


directly fired gas turbine

turbine à gaz à cycle simple


coal fire gas turbine

turbine à gaz alimentée au charbon


oil-fired gas turbine locomotive

locomotive turbo-diesel


pulverised coal fired gas turbine

turbine à gaz fonctionnant au charbon pulvérisé
IN-CONTEXT TRANSLATIONS
gas turbine’ means any rotating machine which converts thermal energy into mechanical work, consisting mainly of a compressor, a thermal device in which fuel is oxidised in order to heat the working fluid, and a turbine; this includes both open cycle and combined cycle gas turbines, and gas turbines in cogeneration mode, all with or without supplementary firing;

«turbine à gaz», tout appareil rotatif qui convertit de l'énergie thermique en travail mécanique et consiste principalement en un compresseur, un dispositif thermique permettant d'oxyder le combustible de manière à chauffer le fluide de travail et une turbine; sont comprises dans cette définition les turbines à gaz à circuit ouvert et les turbines à gaz à cycle combiné, ainsi que les turbines à gaz en mode de cogénération, équipées ou non d'un brûleur supplémentaire dans chaque cas;


All emission limit values set out in this Annex are defined at a temperature of 273,15 K, a pressure of 101,3 kPa and after correction for the water vapour content of the waste gases and at a standardised O2 content of 6 % for medium combustion plants using solid fuels, 3 % for medium combustion plants, other than engines and gas turbines, using liquid and gaseous fuels and 15 % for engines and gas turbines.

Toutes les valeurs limites d'émission figurant dans la présente annexe sont définies pour une température de 273,15 K, une pression de 101,3 kPa et après correction en fonction de la teneur en vapeur d'eau des gaz résiduaires, et pour une teneur normalisée en O2 de 6 % dans le cas des installations de combustion moyennes utilisant des combustibles solides, de 3 % dans le cas des installations de combustion moyennes, autres que les moteurs et turbines à gaz, qui utilisent des combustibles liquides et gazeux et de 15 % dans le cas des m ...[+++]


The Commission further questioned the eligibility of a number of plants to be included in the TNP and requested additional data and/or clarifications concerning the average waste gas flow rates, conversion factors, total rated thermal input and emission limit values applied for certain plants, in particular multi-fuel firing plants and gas turbines.

La Commission s’est par ailleurs interrogée sur le bien-fondé de l’inclusion d’un certain nombre d’installations dans le PNT et a demandé des données complémentaires et/ou des éclaircissements concernant les débits moyens des gaz résiduaires, les facteurs de conversion, la puissance thermique nominale totale et les valeurs limites d’émission appliquées pour certaines installations, en particulier les installations à foyer mixte et les turbines à gaz.


The operator shall include at least the following potential sources of CO emissions: boilers, gas turbines, and other combustion devices producing steam or power, recovery boilers and other devices burning spent pulping liquors, incinerators, lime kilns and calciners, waste gas scrubbing and fuel-fired dryers (such as infrared dryers).

L’exploitant tient compte au minimum des sources potentielles d’émission de CO suivantes: chaudières, turbines à gaz et autres systèmes de combustion produisant de la vapeur ou de l’électricité, chaudières de récupération et autres dispositifs brûlant les lessives résiduaires de cuisson, incinérateurs, fours à chaux et fours de calcination, épuration des effluents gazeux et sécheurs alimentés par des combustibles (tels que sécheurs à infrarouge).


For more results, go to https://pro.wordscope.com to translate your documents with Wordscope Pro!
Immediate/Short-termLonger term | Reduction in demand (e.g. smaller engines)Advanced high-efficiency ICEsImproved hybrid electric designs with petrol, diesel, biodieselBio-diesel; bio-ethanolCo-processing of biomass with fossil fuelsSynthetic fuels from gas/coal-Fischer-TropschBiofuels from ligno-cellulosic feedstocksElectric vehicles (EVs) with advanced battery electricity storageHydrogen with fuel cellsAir transport: hydrogen/gas turbine | Low/medium temperature solar thermal applications for hot water, heating, cooling, industrial processesCombined Cycle Gas Turbine (CCGT)Nuclear fission (Gen III/III+)Wind energy (including offshore/ ...[+++]

Immédiat/court terme Long terme | Réduction de la demande (moteurs plus petits, notamment) Moteurs à explosion à haut rendement Moteurs hybrides améliorés à essence, diesel ou biodiesel Biodiesel et bioéthanol Transformation conjointe de biomasse et de combustibles fossiles Carburants synthétiques à partir de gaz ou de charbon (procédé Fischer-Tropsch) Biocarburants provenant de la filière lignocellulosique Véhicules électriques à batteries à grande capacité Hydrogène et piles à combustible Transport aérien: turbine à hydrogène et à gaz | Applications solaires thermiques à moyenne ou basse température pour eau chaude, chauffage, refroidi ...[+++]


(3) "emission limit value" means the permissible quantity of a substance contained in the waste gases from the combustion plant which may be discharged into the air during a given period; it shall be calculated in terms of mass per volume of the waste gases expressed in mg/Nm3, assuming an oxygen content by volume in the waste gas of 3 % in the case of liquid and gaseous fuels, 6 % in the case of solid fuels and 15 % in the case of gas turbines.

3) "valeur limite d'émission", la quantité admissible d'une substance contenue dans les gaz résiduaires de l'installation de combustion pouvant être rejetée dans l'atmosphère pendant une période donnée; elle est déterminée en masse par volume des gaz résiduaires exprimée en mg/Nm3, rapportée à une teneur en oxygène, dans les gaz résiduaires, de 3 % en volume dans le cas de combustibles liquides ou gazeux, de 6 % dans le cas de combustibles solides et de 15 % dans le cas des turbines à gaz.


- for SO2 and dust from natural gas burning boilers or from gas turbines firing natural gas.

- pour le SO2 et les poussières provenant de brûleurs utilisant du gaz naturel ou de turbines brûlant du gaz naturel,


(12) "gas turbine" means any rotating machine which converts thermal energy into mechanical work, consisting mainly of a compressor, a thermal device in which fuel is oxidised in order to heat the working fluid, and a turbine.

12) "turbine à gaz", tout appareil rotatif qui convertit de l'énergie thermique en travail mécanique et consiste principalement en un compresseur, un dispositif thermique permettant d'oxyder le combustible de manière à chauffer le fluide de travail, et une turbine.


This emission limit value only applies to gas turbines firing light and middle distillates.

Cette valeur limite d'émission ne s'applique qu'aux turbines à gaz brûlant des distillats légers et moyens.


(3) "emission limit value" means the permissible quantity of a substance contained in the waste gases from the combustion plant which may be discharged into the air during a given period; it shall be calculated in terms of mass per volume of the waste gases expressed in mg/Nm3, assuming an oxygen content by volume in the waste gas of 3 % in the case of liquid and gaseous fuels, 6 % in the case of solid fuels and 15 % in the case of gas turbines;

3) "valeur limite d'émission", la quantité admissible d'une substance contenue dans les gaz résiduaires de l'installation de combustion pouvant être rejetée dans l'atmosphère pendant une période donnée; elle est déterminée en masse par volume des gaz résiduaires exprimée en mg/Nm3, rapportée à une teneur en oxygène, dans les gaz résiduaires, de 3 % en volume dans le cas de combustibles liquides ou gazeux, de 6 % dans le cas de combustibles solides et de 15 % dans le cas des turbines à gaz;




datacenter (1): www.wordscope.ca (v4.0.br)

'Fuel-fired gas turbine' ->

Date index: 2021-10-06
w