Boost Your Productivity!Translate documents (Ms-Word, Ms-Excel, ...) faster and better thanks to artificial intelligence!
https://pro.wordscope.com
https://blog. wordscope .com
Coal-fired boiler
Direct fire boiler
Engine room
Evaporator room
Fire room
Fire-box type of boiler
Fire-tube boiler
Firebox boiler
Firebox-type boiler
Firetube boiler
Firetube type of boiler
Galley
Gas boiler
Gas fired boiler
Immersion fire tube boiler
Immersion fired boiler
Internal firebox boiler
Internal furnace boiler
Internally fired boiler
Laundry
Liquid fuel boiler
Loading
Machinery
Multi-fired boiler
Oil-fired boiler
Shell boiler
Smoke-tube boiler
Wood-fired boiler

Traduction de «Internally fired boiler » (Anglais → Français) :

TERMINOLOGIE
voir aussi les traductions en contexte ci-dessous


firebox boiler [ firebox-type boiler | fire-box type of boiler | internal firebox boiler | internal furnace boiler ]

chaudière à foyer intérieur


fire-tube boiler [ firetube boiler | firetube type of boiler | shell boiler | smoke-tube boiler | immersion fired boiler | immersion fire tube boiler ]

chaudière à tubes de fumée [ chaudière à tubes de fumées | chaudière ignitubulaire | générateur à tubes de fumée | chaudière à tubes de flamme | chaudière à tube de flamme ]


liquid fuel boiler | oil-fired boiler

chaudière à combustible liquide | chaudière à mazout | générateur à mazout












accidental poisoning by gases or fumes on ship atomic reactor malfunction in watercraft crushed by falling object on ship excessive heat in:boiler room | engine room | evaporator room | fire room | explosion of boiler on steamship fall from one level to another in watercraft fall on stairs or ladders in watercraft injuries in watercraft caused by:deck | engine room | galley | laundry | loading | machinery | localized fire on ship machinery accident in watercraft

accident de machine sur le bateau chaleur excessive dans la:chaufferie | salle des:chaudières | évaporateurs | machines | chute dans des escaliers ou des échelles sur le bateau chute d'un niveau à un autre sur le bateau écrasement par un objet tombé sur le bateau explosion d'une chaudière sur un bateau à vapeur incendie localisé à bord d'un bateau intoxication accidentelle par des gaz et des fumées sur un bateau lésions traumatiques provoquées sur le bateau par les machines de:blanchisserie | chargement | cuisine | pont | salle des machines | mauvais fonctionnement d'un réacteur atomique à bord d'un bateau
TRADUCTIONS EN CONTEXTE
(2) In every Class A ship fitted with main or auxiliary oil-fired boilers, or internal combustion propelling machinery, the arrangements of sea connections, pumps, and the sources of power for operating them, shall be such as will ensure that a fire in any one compartment will not put all the fire pumps out of action; fire pumps shall not all be located in the same compartment but shall be arranged so that at least one pump and its source of power will remain available if a fire in any one compartment would make it impossible to use the other pump or pumps or their source of power; in some case ...[+++]

(2) Sur tout navire de la classe A muni de chaudières principales ou auxiliaires chauffées au mazout ou mû par des moteurs à combustion interne, les prises d’eau à la mer, les pompes et les sources d’énergie qui les actionnent seront disposées de manière à éviter qu’un incendie dans l’un quelconque des compartiments puisse mettre toutes les pompes d’incendie hors de service. Les pompes d’incendie ne seront pas toutes placées dans le même compartiment mais seront disposées de façon qu’au moins l’une d’elles et sa source d’énergie soient utilisables au cas où un incendie dans un compartiment viendrait à rendre impossible l’utilisation de l ...[+++]


(3) Every Class H ship over 45.7 m in length propelled by internal combustion machinery and having an auxiliary oil-fired boiler situated in the compartment containing that machinery shall, in addition to the requirements of subsections (1) and (2), be provided with at least one foam fire extinguisher of not less than 9 L capacity or one equivalent fire extinguisher as set forth in Schedule IV, suitably stowed in the vicinity of the boiler.

(3) Tout navire de la classe H d’une longueur de plus de 45,7 m, mû par des moteurs à combustion interne et ayant une chaudière auxiliaire chauffée au mazout et située dans le compartiment renfermant ces moteurs, doit satisfaire aux exigences des paragraphes (1) et (2), mais aussi avoir au moins un extincteur à mousse d’une capacité d’au moins 9 L, ou un extincteur équivalent indiqué à l’annexe IV, dûment rangé à proximité de la chaudière.


(3) Every Class G ship propelled by internal combustion machinery and having an auxiliary oil-fired boiler situated in the compartment containing that machinery shall, in addition to the requirements of subsections (1) and (2), be provided with at least one foam fire extinguisher of not less than 9 L capacity or one equivalent fire extinguisher as set out in Schedule IV, suitably stowed in the vicinity of the boiler.

(3) Tout navire de la classe G mû par des moteurs à combustion interne et ayant une chaudière auxiliaire chauffée au mazout située dans le compartiment renfermant ces moteurs, doit satisfaire aux exigences des paragraphes (1) et (2), mais aussi avoir au moins un extincteur à mousse d’une capacité d’au moins 9 L, ou un extincteur équivalent indiqué à l’annexe IV, dûment rangé à proximité de la chaudière.


(3) Every Class B ship propelled by internal combustion machinery and having an auxiliary oil-fired boiler situated in the compartment containing the machinery shall, in addition to the requirements of subsections (1) and (2), be provided with at least one foam fire extinguisher of not less than 9 L capacity or one equivalent fire extinguisher as set out in Schedule IV suitably stowed in the vicinity of the boiler.

(3) Tout navire de la classe B mû par des moteurs à combustion interne et ayant une chaudière auxiliaire chauffée au mazout dans le compartiment renfermant ces moteurs, doit satisfaire aux exigences des paragraphes (1) et (2), mais aussi avoir au moins un extincteur à mousse d’une capacité d’au moins 9 L ou un extincteur équivalent indiqué à l’annexe IV, dûment rangé à proximité de la chaudière.


For more results, go to https://pro.wordscope.com to translate your documents with Wordscope Pro!
(3) Every Class H ship not over 45.7 m in length propelled by internal combustion machinery and having an auxiliary oil-fired boiler situated in the compartment containing that machinery shall, in addition to the requirements of subsections (1) and (2), be provided with at least one foam fire extinguisher of not less than 9 L capacity or one equivalent fire extinguisher as set forth in Schedule IV, suitably stowed in the vicinity of the boiler.

(3) Tout navire de la classe H d’une longueur d’au plus 45,7 m, mû par des moteurs à combustion interne et ayant une chaudière chauffée au mazout située dans le compartiment renfermant ces moteurs, doit satisfaire aux exigences des paragraphes (1) et (2), mais aussi avoir au moins un extincteur à mousse d’au moins 9 L, ou un extincteur équivalent indiqué à l’annexe IV, dûment rangé à proximité de la chaudière.




datacenter (1): www.wordscope.ca (v4.0.br)

'Internally fired boiler' ->

Date index: 2021-12-25
w