Boost Your Productivity!Translate documents (Ms-Word, Ms-Excel, ...) faster and better thanks to artificial intelligence!
https://pro.wordscope.com
https://blog. wordscope .com
Ensure power supply for the tram system
Ensure tram system power supply
Line cord
Maintain electric equipment
Maintain electrical equipment
Maintain tramline power supply
Maintain tramway power supply
Maintaining electrical equipment
No break power supply
No-break power
No-break power supply
Nominal capacity
Nominal output
Nominal power
Nominal power supply
PSU
Power cord
Power pack
Power source
Power supply
Power supply cord
Power supply module
Power supply of analog trunk
Power supply of analogue trunk
Power supply source
Power supply unit
Power unit
Power-supply cord
Provide power distribution
Rated capacity
Rated output
Rated power
Rating
SMPS
SPS
Supply source
Supply unit
Supply with power outlets
Switched mode power supply
Switched power supply circuit
Switching mode power supply
Switching power supply
Switching supply
Test and maintain power supply
UPS
Uninterrupted power supply
Uninterruptible feeding
Uninterruptible power
Uninterruptible power supply
Uninterruptible power system

Translation of "Nominal power supply " (English → French) :

TERMINOLOGY
see also In-Context Translations below


ensure power supply for the tram system | maintain tramway power supply | ensure tram system power supply | maintain tramline power supply

assurer l'alimentation électrique du système de tramway


power supply | power supply unit | PSU | power supply module | power supply source | power pack | supply source | supply unit | power unit | power source

bloc d'alimentation | module d'alimentation | unité d'alimentation


uninterruptible power system [ UPS | no break power supply | no-break power | uninterruptible power | uninterruptible power supply | no-break power supply | uninterrupted power supply | uninterruptible feeding ]

alimentation sans coupure [ UPS | alimentation sans interruption | unité d'alimentation permanente | alimentation ininterruptible ]


switching mode power supply | SMPS | switched mode power supply | switching power supply | SPS | switching supply | switched power supply circuit

alimentation à découpage | alimentation commutée | source d'alimentation à découpage | source d'alimentation commutée | bloc d'alimentation à découpage | bloc d'alimentation commutée


rated output | rated capacity | rating | nominal output | nominal power | nominal capacity | rated power

puissance nominale | puissance normale


power supply of analog trunk | power supply of analogue trunk

alimentation d'un circuit analogique


power cord [ line cord | power supply cord | power-supply cord ]

cordon d'alimentation [ cordon de secteur | cordon secteur ]


maintain electric equipment | maintaining electrical equipment | maintain electrical equipment | test and maintain power supply

entretenir des équipements électriques


bring power to stage, lights, sound, and video | provide power for light, stage, sound, video and recording purposes | provide power distribution | supply with power outlets

assurer la distribution d'électricité
IN-CONTEXT TRANSLATIONS
30 (1) A register and all ancillary equipment that operate from the main power supply shall remain within the applicable limits of error when tested with voltages from 90 to 110 per cent of the nominal voltage.

30 (1) L’enregistreur et tous les dispositifs auxiliaires qui sont alimentés par la source d’alimentation principale doivent respecter les marges de tolérance applicables lorsqu’ils sont mis à l’essai à une tension de 90 à 110 pour cent de la tension nominale.


4. For the power supply: the nominal value of the AC voltage supply and/or the limits of DC supply.

4. Pour l'alimentation électrique: la valeur nominale de l'alimentation en courant alternatif et/ou les limites de l'alimentation en courant continu.


‘type of electrical audible warning device’ means audible warning devices not essentially differing among themselves, particularly in respect of the following aspects: trade mark or name, operating principle, type of power supply (direct current, alternating current, compressed air), outer shape of the casing, shape and dimensions of the diaphragm(s), shape or type of the sound emission orifice(s), nominal sound frequencies, nominal supply voltage and, in the case of warning devices supplied d ...[+++]

2) «type d’avertisseur sonore électrique»: les avertisseurs sonores ne présentant pas entre eux de différences essentielles, notamment en ce qui concerne les éléments ci-après: la marque de fabrique ou de commerce, le principe de fonctionnement, le type d’alimentation (courant continu, courant alternatif, air comprimé), la forme extérieure du boîtier, la forme et les dimensions de la ou des membranes, la forme ou le genre du ou des orifices d’émission du son, les fréquences nominales du son, la tension nominale d’alimentation et, dans le cas des avertisseurs alimentés directement par une source externe d’air comprimé, la pression nominal ...[+++]


0,5 % at ambient temperature 20 °C ± 3 °C, ambient humidity 60 % ± 15 %, nominal values for power supply;

0,5 % à une température ambiante de 20 °C ± 3 °C, une humidité ambiante de 60 % ± 15 %, aux valeurs nominales d'alimentation électrique,


For more results, go to https://pro.wordscope.com to translate your documents with Wordscope Pro!
For the power supply: the nominal value of the AC voltage supply and/or the limits of DC supply.

Pour l’alimentation électrique: la valeur nominale de l’alimentation en courant alternatif et/ou les limites de l’alimentation en courant continu.


4. For the power supply: the nominal value of the AC voltage supply and/or the limits of DC supply.

4. Pour l'alimentation électrique: la valeur nominale de l'alimentation en courant alternatif et/ou les limites de l'alimentation en courant continu.


4. For the power supply: the nominal value of the AC voltage supply and/or the limits of DC supply.

4. Pour l'alimentation électrique: la valeur nominale de l'alimentation en courant alternatif et/ou les limites de l'alimentation en courant continu


0,5% at ambient temperature 20°C +/- 3°C, ambient humidity 60% +/- 15%, nominal values for power supply;

0,5 % à une température ambiante de 20 °C ± 3 °C, une humidité ambiante de 60 % ± 15 %, aux valeurs nominales d'alimentation électrique;


Any ripple in the power supply voltage measured at the monitoring port of the power supply must not exceed 1,5 % of the STU's nominal operating voltage.

L'ondulation de la tension d'alimentation mesurée à la sortie de contrôle de l'alimentation électrique ne doit pas dépasser de 1,5 % la tension de service normale de l'ETS.


The power supply voltage must be maintained at ± 10 % of the nominal operating voltage of the system.

La tension de bord stabilisée ne doit pas dévier de plus de ± 10 % par rapport à la tension de service nominale de l'ETS.


w