Boost Your Productivity!Translate documents (Ms-Word, Ms-Excel, ...) faster and better thanks to artificial intelligence!
https://pro.wordscope.com
https://blog. wordscope .com
Cabin pressure relief outlet valve
Conduct media outlets research
Delivery valve
Discharge outlet
Discharge valve
Gate outlet
Outlet
Outlet cap
Outlet cap plug
Outlet gate
Outlet port
Outlet reducer
Outlet valve
Outlet valve cap
Outlet valve cap plug
Outlet valve reducer
Perform media outlet research
Perform media outlets research
Performing media outlets research
Valve outlet

Translation of "Outlet valve " (English → French) :

TERMINOLOGY
see also In-Context Translations below
outlet valve cap plug [ outlet cap plug | outlet cap | outlet valve cap ]

bouchon de vidange [ bouchon du dispositif de vidange ]


delivery valve | discharge valve | outlet valve

clapet de refoulement | soupape de refoulement


outlet port | outlet | valve outlet

orifice de sortie | sortie


discharge outlet [ gate outlet | valve outlet ]

conduits d'écoulement [ registre de vidange | robinet d'évacuation | orifice de déchargement ]


outlet gate | outlet valve

vanne de vidange | vanne d'écoulement




discharge valve [ delivery valve | outlet valve ]

soupape de refoulement [ clapet de refoulement ]




cabin pressure relief outlet valve

clapet de décharge de pression cabine


conduct media outlets research | performing media outlets research | perform media outlet research | perform media outlets research

réaliser une étude sur des supports médias
IN-CONTEXT TRANSLATIONS
(b) with outlet valves for the containers, so arranged that the solutions will be released from the containers simultaneously and in proper proportions by the operation of a control-wheel or control-handle, in either case so placed as not to be rendered inaccessible by a fire in the space intended to be protected; and

b) de soupapes disposées de façon que les solutions puissent sortir simultanément des récipients, en proportions convenables, au simple maniement d’un volant ou d’une poignée de commande qu’un incendie dans le local à protéger ne saurait rendre inaccessible; et


(11) Notwithstanding the provisions of subsection (10), where a new or existing fishing vessel is equipped with an oil fired power boiler for main or auxiliary steam, the provisions of subsection (8) shall apply to every fuel tank outlet valve or cock.

(11) Par dérogation au paragraphe (10), lorsqu’un bateau de pêche neuf ou existant est muni d’une chaudière chauffant au mazout pour l’alimentation des machines principales ou auxiliaires, les dispositions du paragraphe (8) seront applicables à toutes les soupapes ou robinets de sortie de la soute à combustible.


(10) The provisions of subsection (8) shall not apply to an existing fishing vessel where, in the opinion of an inspector, the fitting of a remote control to the fuel tank outlet valve or cock would be impracticable, but in such a case, means shall be provided whereby the propelling engine may be stopped from a position outside the compartment in which the propelling engine is situated.

(10) Les dispositions du paragraphe (8) ne seront pas applicables aux bateaux de pêche existants lorsqu’un inspecteur est d’avis qu’il serait pratiquement impossible d’installer une commande à distance pour une soupape ou un robinet de sortie de la soute à combustible; en pareil cas, il sera prévu un moyen d’arrêter la machine motrice d’un point situé à l’extérieur du compartiment où se trouve cette machine.


Where relief valves are fitted to bilge pumps that have sea connections, those valves and their outlets shall be fitted in readily visible locations above the lowest working-level platform.

Lorsque des soupapes de sûreté sont installées sur les pompes de cale ayant des prises d’eau à la mer, ces soupapes et leur sortie doivent être installées à des endroits facilement visibles au-dessus de la plate-forme de travail la plus basse.


For more results, go to https://pro.wordscope.com to translate your documents with Wordscope Pro!
17 (1) Each steam outlet from a boiler, except safety valve and superheater connections, shall be provided with a suitable shut-off valve located close to the boiler.

17 (1) Chaque prise de vapeur d’une chaudière, sauf les raccords de la soupape de sûreté et du surchauffeur, doit être munie d’un robinet d’arrêt convenable situé près de la chaudière.


To classify an oxidising gas, tests or calculation methods as described in ISO 10156 as amended, “Gases and gas mixtures — Determination of fire potential and oxidising ability for the selection of cylinder valve outlet” shall be performed’.

Pour classer un gaz comburant, il est nécessaire de disposer de données obtenues soit par des épreuves, soit par calcul selon la méthode ISO 10156 “Gaz et mélanges de gaz — Détermination du potentiel d’inflammabilité et d’oxydation pour le choix des raccords de sortie de robinets”, telle que modifiée».


Flammability shall be determined by tests or, for mixtures where there are sufficient data available, by calculation in accordance with the methods adopted by ISO (see ISO 10156 as amended, Gases and gas mixtures — Determination of fire potential and oxidising ability for the selection of cylinder valve outlet).

L’inflammabilité est déterminée par des essais ou, lorsqu’il s’agit de mélanges sur lesquels des données suffisantes sont disponibles, par des calculs effectués conformément aux méthodes approuvées par l’ISO (voir la norme ISO 10156, telle que modifiée, Gaz et mélanges de gaz — Détermination du potentiel d’inflammabilité et d’oxydation pour le choix des raccords de sortie de robinets).


At each measuring point, the noise level of release and escape of air from the external lines coupled to the air outlet valves of compressors shall be more than 10 dB lower than the noise level of the compressor.

En tous points de mesure, le niveau de bruit d'évacuation et d'échappement d'air des conduits extérieurs du motocompresseur, raccordés à la vanne de sortie d'air de ce dernier, doit être inférieur de plus de 10 dB par rapport au niveau de bruit du motocompresseur.


(i) the outlet valves must be fitted in such a way as to enable the extinguishing agent to be distributed evenly and must be designed to enable the extinguishing agent to mix evenly and completely with the air to prevent stong local concentrations of the agent from occurring;

i) les buses de sortie doivent être installées de manière à permettre une répartition régulière de l'agent extincteur et leur conception doit permettre à l'agent extincteur de se mélanger de manière homogène et complète à l'air pour éviter qu'il ne se produise de fortes concentrations locales de cet agent;


(j) the system of piping and outlet valves must be designed in such a way as to enable the extinguishing agent to be released into the area to be protected within 10 seconds, supposing that the extinguishing agent is in a fluid state at an ambient temperature of 0 °C;

j) la conception du système de canalisations et des buses de sortie doit permettre l'écoulement dans le local à protéger de l'agent extincteur en 10 secondes en supposant que cet agent extincteur se trouve à l'état fluide pour une température ambiante de 0 °C;




datacenter (1): www.wordscope.ca (v4.0.br)

'Outlet valve' ->

Date index: 2023-10-01
w