Translation of "Particulate sampling filter " (English → French) :

TERMINOLOGY
see also In-Context Translations below
particulate sampling filter

filtre de prélèvement des particules


particulate sample probe | particulate sampling probe | PSP [Abbr.]

sonde de prélèvement des particules


absolute filter [ high efficiency filter | high efficiency particulate air filter | HEPA filter | high efficiency air filter | HEAF filter | ultra filter | high-efficiency particle filter ]

filtre absolu [ filtre à haute efficacité pour les particules de l'air | filtre H.E.P.A. | filtre HEPA | filtre à haute efficacité | filtre à très haute efficacité | filtre de très haute efficacité | filtre THE | filtre à particules à haute efficacité | filtre HEAF ]


absolute filter | HEPA filter | high efficiency particulate air filter | high efficiency filter

filtre absolu | filtre à haute efficacité


high efficiency particulate air filter | HEPA filter | high efficiency filter | absolute filter

filtre haute efficacité pour les particules de l'air | filtre absolu | filtre H.E.P.A.


absolute filter | High Efficiency Particulate Air filter | HEPA filter [Abbr.]

filtre à air à très haute efficacité | filtre à haute performance | filtre à particules à haute efficacité | filtre à très haute efficacité | filtre absolu | ultra filtre | filtre HEPA [Abbr.] | filtre THE [Abbr.]


high efficiency particulate air filter | HEPA filter | absolute filter

filtre haute efficacité pour les particules de l'air | filtre absolu | filtre H.E.P.A.


mechanical filter respirator [ particle-removing respirator | particulate removing respirator | particulate filter respirator ]

respirateur à action mécanique [ respirateur à filtre de particules ]


Gas sampling line filter

filtre pour conduite d’échantillonnage de gaz


Method of sampling and testing tobacco : Determination of benzo(a)pyrene in total particulate matter of tobacco smoke

Méthode d'échantillonnage et d'essai du tabac : Détermination du benzo(a)pyrène dans la matière particulière totale de la fumée de tabac
IN-CONTEXT TRANSLATIONS
A sample of the diluted exhaust gas is taken from the dilution tunnel DT of a partial flow or full flow dilution system through the particulate sampling probe PSP and the particulate transfer tube PTT by means of the sampling pump P. The sample is passed through the filter holders(s) FH that contain the particulate sampling filters.

Un échantillon des gaz d'échappement dilués est prélevé dans le tunnel de dilution DT d'un système de dilution en circuit partiel ou en circuit principal; on le fait passer ensuite à travers la sonde de prélèvement des particules PST et le tube de transfert des particules PTT au moyen de la pompe de prélèvement P. L'échantillon passe à travers les porte-filtres FH qui reçoivent les filtres de prélèvement des particules.


To determine the mass of the particulates, a particulate sampling system, particulate sampling filters, microgram balance, and a temperature and humidity controlled weighing chamber, are required.

Pour déterminer la masse des particules, il faut disposer d'un système d'échantillonnage, de filtres pour le prélèvement des particules, d'une microbalance et d'une chambre de pesée à température et humidité contrôlées.


The sample is then passed through the filter holder(s) FH that contain the particulate sampling filters.

Il passe ensuite à travers des porte-filtres FH qui reçoivent les filtres de prélèvement des particules.


To determine the mass of the particulates, a particulate sampling system, particulate sampling filters, a microgram balance and a temperature and humidity controlled weighing chamber are required.

Pour déterminer la masse des particules, il faut disposer d'un système d'échantillonnage, de filtres pour le prélèvement des particules, d'une microbalance et d'une chambre de pesée à humidité contrôlée.


For more results, go to https://pro.wordscope.com to translate your documents with Wordscope Pro!
Mass of the diluted exhaust sample passed through the particulate sampling filters

Masse de gaz d'échappement dilués traversant les filtres à particules


A sample of the diluted exhaust gas is taken from the dilution tunnel DT of a partial flow or full flow dilution system through the particulate sampling probe PSP and the particulate transfer tube PTT by means of the sampling pump P. The sample is passed through the filter holder(s) FH that contain the particulate sampling filters.

Un échantillon de gaz d'échappement dilués est prélevé dans le tunnel de dilution DT d'un système de dilution en circuit principal ou en dérivation par la sonde de prélèvement de particules PSP et le tube de transfert de particules PTT, via la pompe de prélèvement P. L'échantillon est envoyé au travers du ou des porte-filtres FH contenant les filtres de prélèvement de particules.


To determine the mass of the particulates, a particulate sampling system, particulate sampling filters, a microgram balance, and a temperature and humidity controlled weighing chamber, are required.

Un système de prélèvement des particules, des filtres de prélèvement des particules, une microbalance et une chambre de pesée à contrôle de température et d'humidité sont nécessaires pour déterminer la masse de particules.


A sample of the diluted exhaust gas is taken from the dilution tunnel DT of a partial flow or full flow dilution system through the particulate sampling probe PSP and the particulate transfer tube PTT by means of the sampling pump P. The sample is passed through the filter holders(s) FH that contain the particulate sampling filters.

Un échantillon des gaz d'échappement dilués est prélevé dans le tunnel de dilution DT d'un système de dilution en circuit partiel ou en circuit principal; on le fait passer ensuite à travers la sonde de prélèvement des particules PST et le tube de transfert des particules PTT au moyen de la pompe de prélèvement P. L'échantillon passe à travers les porte-filtres FH qui reçoivent les filtres de prélèvement des particules.


To determine the mass of the particulates, a particulate sampling system, particulate sampling filters, a microgram balance and a temperature and humidity controlled weighing chamber are required.

Pour déterminer la masse des particules, il faut disposer d'un système d'échantillonnage, de filtres pour le prélèvement des particules, d'une microbalance et d'une chambre de pesée à humidité contrôlée.


The determination of the particulate emissions requires a dilution system capable of maintaining the temperature of the diluted exhaust gas at or below 325 K (52 oC), a particulate sampling system, specified particulate sampling filters, and a microgram balance which shall be placed in an air conditioned weighing chamber.

La détermination des émissions de particules requiert un système de dilution capable de maintenir la température des gaz d'échappement dilués égale ou inférieure à 325 K (52 oC), un système de prélèvement des particules, des filtres de prélèvement des particules prescrits et une microbalance qui doit être placée dans une chambre de pesée à air conditionné.