Boost Your Productivity!Translate documents (Ms-Word, Ms-Excel, ...) faster and better thanks to artificial intelligence!
https://pro.wordscope.com
https://blog. wordscope .com
Air pressure operated valve
Automatic pressure differential relief valve
Directly operated pressure control valve
Fuel tank pressure operated interconnect valve
POA valve
Pilot operated pressure control valve
Pressure operated interconnect valve
Pressure-operated altitude valve

Traduction de «Pressure operated interconnect valve » (Anglais → Français) :

TERMINOLOGIE
voir aussi les traductions en contexte ci-dessous
pressure operated interconnect valve

soupape de liaison actionnée par pression


fuel tank pressure operated interconnect valve

robinet manométrique d'intercommunication de réservoir de carburant


pressure-operated altitude valve [ POA valve ]

régulateur de pression altimétrique


automatic pressure differential relief valve [ automatically operating pressure differential relief valve ]

soupape différentielle automatique [ soupape de détente automatique commandée par la différence de pression ]




directly operated pressure control valve

appareil de réglage de la pression actionné directement


pilot operated pressure control valve

appareil de réglage de la pression indirect | appareil de réglage de la pression piloté
TRADUCTIONS EN CONTEXTE
(2) When two or more boilers or pressure vessels are connected and are used at a common operating pressure, they shall each be fitted with at least one safety valve or other equivalent fitting to maintain pressure at or below the maximum allowable working pressure of the boiler or pressure vessel that has the lowest maximum allowable working pressure.

(2) Si deux ou plusieurs chaudières ou réservoirs sous pression sont reliés les uns aux autres et sont soumis à une pression de fonctionnement commune, chacun d’eux doit être muni d’au moins une soupape de sécurité ou un dispositif accessoire équivalent qui maintient la pression à un niveau égal ou inférieur à la pression de fonctionnement maximale autorisée de la chaudière ou du réservoir dont la pression de fonctionnement maximale autorisée est la plus basse.


5. Where a propane dispenser has a vapour separator with a vapour release valve of the float-operated type, the vapour release valve shall have a continuous bleed or other means to ensure satisfactory operation at differential pressures up to 700 kPa.

5. Lorsque le distributeur de propane comporte un séparateur de vapeur muni d'une soupape de décharge de la vapeur du type à flotteur, cette soupape doit être pourvue d'un purgeur continu ou d'un autre dispositif assurant un fonctionnement satisfaisant à des pressions différentielles pouvant atteindre 700 kPa.


(b) the operating pressure of the safety valve must not be more than one and one-half times the operating pressure of the steam boiler to which it is fitted; and

b) la pression de fonctionnement de la soupape de sécurité ne dépasse pas une fois et demie la pression de fonctionnement de la chaudière à vapeur à laquelle elle est fixée;


48 (1) All piping, valves and fittings shall be inspected and tested after assembly and prior to commencing operations for the first time and be proven gastight at a pressure not less than the working pressure of the tank, pump or device to which they are connected, or at 150 psig, if this is a higher pressure.

48 (1) Tous les tuyaux, soupapes et accessoires seront inspectés et soumis à des essais après leur assemblage et avant de commencer les opérations pour la première fois, et leur étanchéité au gaz sera éprouvée à une pression qui ne sera pas inférieure à la pression de service du réservoir, de la pompe ou du dispositif auquel ils sont raccordés, ou à une pression manométrique d’au moins 150 livres par pouce carré, suivant le cas.


For more results, go to https://pro.wordscope.com to translate your documents with Wordscope Pro!
(5) All piping, valves and fittings shall be tested after installation and before operations begin at a pressure 50 per cent in excess of the maximum working pressure, but in no case less than 5 psig and that pressure shall be maintained for a period of not less than 30 minutes.

(5) Après leur installation et avant que l’exploitation ne commence, les canalisations, les soupapes et garnitures seront éprouvées à une pression de 50 pour cent supérieure à la pression de service maximum, mais en aucun cas cette pression ne sera inférieure à cinq livres par pouce carré au manomètre et cette pression d’essai sera maintenue pour une période d’au moins 30 minutes.


Content of the national legislation: Exemption from the requirements of 6.7 and 6.8 of the ADR for the carriage by road of nominally empty uncleaned storage tanks (for storage at fixed premises) for the purpose of cleaning, repair, testing or scrapping, provided that (a) as much of the pipework which was connected to the tank as was reasonably practicable to remove from it has been removed; (b) a suitable pressure relief valve, which shall remain operational during the carriage, is fitted to the tank; and (c) subject to (b) above all openings in the tank and in any pipework ...[+++]

Contenu de la législation nationale: exemption des prescriptions figurant sous 6.7 et 6.8 de l’ADR pour le transport par route de citernes fixes nominalement vides et non nettoyées (pour leur entreposage dans des lieux fixes) en vue de leur nettoyage, réparation, mise à l’essai ou mise à la ferraille, à condition que: a) tous les tuyaux fixés à la citerne qu’il est raisonnablement possible d’enlever aient été enlevés; b) la citerne ait été équipée d’un dispositif de décompression adéquat, qui doit rester opérationnel pendant le transport; et c), sous réserve du point b), toutes les ouvertures dans la citerne et dans la tuyauterie fixée à la citerne aient été scellées de manière à empêcher des matières dangereuses de s’échapper ...[+++]


"interconnection agreements" means agreements between interconnected transmission system operators that are designed to ensure the interoperability of the interconnection point and may cover energy specification (including pressure, temperature and chemical gas specifications), changes in flow rates and the operation of the interconnection point;

"accords de raccordement": accords entre les gestionnaires de réseau de transport raccordés qui visent à garantir l'interopérabilité du point de raccordement et peuvent inclure des données énergétiques (notamment sur la pression, la température et sur le gaz chimique) ainsi que la modification du niveau des flux et le fonctionnement du point de raccordement ;


2.2. In systems dependent on an energy supply 2.2.1. The energy supply must be protected from excess pressure by a pressure limiting valve which operates at the pressure T. 2.3. Protection of steering transmission 2.3.1.

2.1.4. Combinaison de timoneries de direction Une combinaison de timoneries mécanique, hydraulique et électrique doit être conforme aux prescriptions des paragraphes 2.1.1, 2.1.2 et 2.1.3 ci-dessus.


The steering transmission must be protected from excess pressure by a pressure limiting valve which operates between 1,5T and 2,2T. 2.4. Tractor/trailer alignment 2.4.1.

2.2. Prescriptions relatives aux essais en cas de défaillance 2.2.1.


8.14.5. Receptacle connectors, piping and other fittings subjected to the pressure in the receptacles, and joints between the reducing valve and the distribution pipe: - leak test, carried out with a foaming substance, at the operating pressure.

8.14.5. Raccords aux récipients, liaisons et armatures qui sont soumis à la pression des récipients ainsi que raccord du détendeur à la canalisation de distribution: - épreuve d'étanchéité, réalisée au moyen d'un produit moussant, sous la pression de service.




datacenter (1): www.wordscope.ca (v4.0.br)

'Pressure operated interconnect valve' ->

Date index: 2024-02-12
w