Traduction de «fuel fire shut-off valve » (Anglais → Français) :

TERMINOLOGIE
voir aussi les traductions en contexte ci-dessous




fuel shut-off valve | fuel shut-off | fuel fire shut-off valve | fuel shut-off cock

robinet d'isolement | robinet d'arrêt carburant | robinet coupe-feu carburant | coupe-feu


fire shut-off valve [ fire wall shut-off valve | fire shutoff valve ]

vanne coupe-feu


fire shut-off valve [ fire wall shut-off valve ]

robinet coupe-feu


hydraulic fire shut-off valve

robinet coupe-feu hydraulique


fuel cut-out | fuel shut-off cock | shut-off valve

robinet coupe-feu


sand trap shut-off valve | sand trap with shut-off valve

bloc-éjecteur de sable


wheels-up landing fuel shut-off valve

vanne d'arrêt de carburant


TRADUCTIONS EN CONTEXTE
The vehicle may have a second ECU compared to the parent vehicle, provided that the ECU is only used to control the injectors, additional shut-off valves and the data acquisition from additional sensors.

Le véhicule peut disposer d’une seconde commande électronique, à la différence du véhicule parent, pourvu que cette commande électronique ne soit utilisée que pour contrôler les injecteurs, des obturateurs supplémentaires et l’acquisition de données à partir de capteurs supplémentaires.


(4) In every Class B ship over 22.9 m in length carrying more than 12 passengers, at least one of the power fire pumps shall be fitted with an automatic control whereby full pressure will be maintained on the fire mains at all times while passengers are on board excepting that where piping is liable to frost damage such piping may be maintained in a drained condition provided the shut-off valve and drainage ...[+++]

(4) Sur tout navire de la classe B long de plus de 22,9 m et transportant plus de 12 passagers, au moins l’une des pompes d’incendie mécaniques aura une commande automatique permettant de maintenir en tout temps la pression dans les collecteurs pendant que des passagers seront à bord, mais si le gel risque d’endommager certains tronçons des conduites, ces tronçons peuvent être vidangés et demeurer dans cet état, à condition que la soupape d’arrêt et les robinets de vidange soient situés en un endroit facilement accessible et qu’un manomètre soit installé sur les tronçons vidangeables des conduites, juste à côté de la soupape d’arrêt.


(2) Main fuel supply lines shall be provided with fuel shut-off valves whereby fuel to boilers, boiler rooms and compartments can be cut off when necessary.

(2) Les principaux tuyaux d’alimentation en combustible doivent avoir des soupapes d’arrêt qui permettent, au besoin, de couper l’alimentation aux chaudières et aux chambres ou compartiments des chaudières.


(2) Sections of pipelines between shut-off valves and compressors, or shut-off valves and positive displacement pumps, shall be equipped with safety relief valves or bypasses set to discharge at a pressure not less than 240 psig and not over 400 psig.

(2) Les parties des canalisations comprises entre les soupapes d’arrêt et les pompes positives à piston-plongeur devront être munies de soupapes de sûreté ou d’orifices de dérivation réglés pour s’ouvrir à une pression comprise entre 240 et 400 livres par pouce carré.


For more results, go to https://pro.wordscope.com to translate your documents with Wordscope Pro!
(3) An excess flow valve or other automatic device as prescribed in subsection (1) is not required for withdrawal connections of tanks with a water capacity of 1,500 Imperial gallons or less if the connection is protected by a controlling orifice not exceeding 5/16 inch diameter on vapour withdrawal and not exceeding 1/8 inch diameter on liquid withdrawal, a manually operated shut-off valve and pressure-reducing regulator, all of which are assembled to the connection as prescribed in 2.2(d), Division II of the 1958 edition of ...[+++]

(3) Les soupapes d’excès de débit ou autres dispositifs automatiques prescrits au paragraphe (1) ne sont pas requis dans le cas des raccords d’extraction des réservoirs dont la capacité en eau est de 1 500 gallons impériaux ou moins, si le raccord est protégé par un orifice de contrôle dont le diamètre n’excède pas 5/16 de pouce pour l’extraction de gaz ni 1/8 de pouce pour l’extraction de liquide, par une soupape d’arrêt à commande manuelle et par un régulateur manodétendeur, tous ces dispositifs étant montés sur le raccordement comme il est prescrit à l’article 2.2(d), division II de l’édition de 1958 de la brochure n 58 de l’Association nationale de protect ...[+++]


(2) The shut-off valves for the shore supply and the ship’s fire main connection shall be clearly and permanently marked to show their purpose, and means shall be provided to prevent the operation of those valves by any unauthorized person.

(2) Les soupapes de fermeture du raccordement à la source d’approvisionnement terrestre et au collecteur d’incendie du navire porteront des indications claires et de caractère permanent concernant leur usage, et des mesures seront prises pour empêcher la manoeuvre de ces soupapes par une personne non autorisée.


description of the equipment installed in the plant to limit the consequences of major accidents for human health and environment, including for example detection/protection systems, technical devices for limiting the size of accidental releases, including water spray; vapour screens; emergency catch pots or collection vessels; shut-off-valves; inerting systems; fire water retention.

description des équipements mis en place dans l'installation pour limiter les conséquences d'accidents majeurs pour la santé humaine et l'environnement, notamment les systèmes de détection/protection, les dispositifs techniques visant à limiter l'ampleur des rejets accidentels, y compris les dispositifs de pulvérisation d'eau, les écrans de vapeur, les cuves et bassins de captage ou de collecte d'urgence, les vannes d'arrêt, les systèmes de neutralisation et les systèmes de rétention des eaux d'incendie.


flexible fuel line (if upstream of first automatic shut-off valve or other safety devices).

flexible de carburant (si en amont de la première vanne d’arrêt automatique ou d’autres dispositifs de sécurité).


6. The hydrogen fuel supply lines must be secured with an automatic shut-off valve mounted directly on or within the container.

6. Les tuyaux d’alimentation en carburant hydrogène doivent être sécurisés par une vanne d’arrêt automatique montée directement sur ou dans le réservoir.


7. In the event of an accident, the automatic shut-off valve mounted directly on or within the container shall interrupt the flow of gas from the container.

7. En cas d’accident, la vanne d’arrêt automatique montée directement sur ou dans le réservoir doit interrompre le débit de gaz en provenance du réservoir.