Boost Your Productivity!Translate documents (Ms-Word, Ms-Excel, ...) faster and better thanks to artificial intelligence!
https://pro.wordscope.com
https://blog. wordscope .com
Analysis of polymer
Analysis using chromatography
Analysis using vapourisation
Applying chromatography software
Chromatography of gas
Chromatography on a basic silica gel plate
Chromatography software applying
Circular chromatography
Electrophoresis in polyacrylamide-SDS gels
Flat-bed chromatography
GC-MS
GFC
GPC
Gas chromatography
Gas chromatography-mass spectrometry
Gel chromatography
Gel filtration
Gel filtration chromatography
Gel permeation chromatography
Mol sieve
Molecular exclusion chromatography
Molecular sieve chromatography
Planar chromatography
Plane chromatography
Polymer analysis
RP chromatography
Radial chromatography
Reverse phase chromatography
Reversed phase chromatography
Reversed phase partition chromatography
Reversed-phase chromatography
Ring chromatography
SDS-PAGE analysis
SDS-gel electrophoresis
SDS-polyacrylamide gel electrophoresis
SEC
Size exclusion chromatography
Use chromatography software
Using chromatography software

Translation of "gel chromatography " (English → French) :

TERMINOLOGY
see also In-Context Translations below
gel chromatography | gel filtration | gel filtration chromatography | gel permeation chromatography | mol sieve | molecular exclusion chromatography | molecular sieve chromatography | size exclusion chromatography | GFC [Abbr.] | GPC [Abbr.] | SEC [Abbr.]

chromatographie d'exclusion | chromatographie par filtration sur gel | chromatographie par perméation de gel | chromatographie sur gel | chromatographie sur gel perméable | gel-filtration | tamisage moléculaire | CPG [Abbr.]


chromatography on a basic silica gel plate

chromatographie sur plaque de gel de silice basique


GPC | polymer analysis | analysis of polymer | gel permeation chromatography

chromatographie par perméation de gel | chromatographie sur gel perméable


chromatography software applying | using chromatography software | applying chromatography software | use chromatography software

utiliser un logiciel de chromatographie


reversed-phase chromatography | RP chromatography | reversed phase chromatography | reverse phase chromatography | reversed phase partition chromatography

chromatographie à polarité de phase inversée | chromatographie en phase inverse | chromatographie en phase inversée | chromatographie de partage en phase inversée


analysis using chromatography | chromatography of gas | analysis using vapourisation | gas chromatography

chromatographie en phase gazeuse | chromatographie gazeuse


gas chromatography/mass spectrometry | gas chromatography/mass spectroscopy | gas chromatography-mass spectrometry | GC-MS | GC/MS [Abbr.]

chromatographie en phase gazeuse couplée à la spectrométrie de masse | chromatographie gazeuse-spectrométrie de masse | GC/MS [Abbr.]


flat-bed chromatography | planar chromatography | plane chromatography

chromatographie de surface


circular chromatography | radial chromatography | ring chromatography

chromatographie circulaire | chromatographie radiale


SDS-gel electrophoresis [ SDS-polyacrylamide gel electrophoresis | electrophoresis in polyacrylamide-SDS gels | SDS-PAGE analysis ]

électrophorèse sur gel de polyacrylamide en présence de SDS [ électrophorèse sur gel-SDS | électrophorèse sur gel de SDS ]
IN-CONTEXT TRANSLATIONS
The sterols and triterpene dialcohols fraction is separated from the unsaponifiable matter by thin-layer chromatography on a basic silica gel plate. The fractions recovered from the silica gel are transformed into trimethylsilyl ethers and then analysed by capillary column gas chromatography.

La fraction des stérols et des diols triterpéniques est séparée de l'insaponifiable par chromatographie en couche mince sur une plaque de gel de silice basique; les fractions récupérées dans le gel de silice sont transformées en triméthylsilyléthers qui sont ensuite analysés par chromatographie en phase gazeuse sur colonne capillaire.


Addition of a suitable internal standard to the fat or oil, then fractionation by chromatography on a hydrated silica gel column. Recovery of the fraction eluted first under the test conditions (whose polarity is less than that of the triglycerides), then direct analysis by capillary column gas-liquid chromatography.

La matière grasse, additionnée d'un étalon interne approprié, est fractionnée par chromatographie sur colonne de gel de silice hydraté; la fraction éluée en premier dans les conditions de l'essai (à polarité inférieure à celle des triglycérides) est récupérée, puis analysée directement par chromatographie en phase gazeuse sur colonne capillaire.


The alcoholic fraction is separated from the unsaponifiable matter by chromatography on a layer of potassium hydroxide impregnated silica gel; the alcohols recovered from the silica gel are transformed into trimethylsilyl ethers and analyzed by capillary gas chromatography.

La matière grasse, additionnée de 1-eicosanol comme standard interne, est saponifiée avec de l'hydroxyde de potassium en solution dans l'éthanol, puis l'insaponifiable est extrait avec de l'éther éthylique. La fraction des alcools est séparée de l'extrait insaponifiable par chromatographie sur plaque de gel de silice basique; les alcools récupérés dans le gel de silice sont transformés en triméthylsilyléthers et analysés par chromatographie en phase gazeuse en colonne capillaire.


3.2.4. Precoated plates for thin layer chromatography, 20 × 20 cm, coated with silica gel G (thickness 0,25 or 0,3 mm).

3.2.4. Plaques pour chromatographie sur couche mince prêtes à l'emploi, 20 × 20 cm, recouvertes de gel de silice G (épaisseur 0,25 ou 0,3 mm).


For more results, go to https://pro.wordscope.com to translate your documents with Wordscope Pro!
4.2.1. Precoated 20 × 20 cm plates for thin layer chromatography coated with polyamide gel (0,15 mm thick) with the addition of a fluorescent indicator.

4.2.1. Plaques pour chromatographie sur couche mince prêtes à l'emploi, 20 × 20 cm recouvertes de gel de polyamide (épaisseur: 0,15 mm) additionné d'un indicateur de fluorescence.


w