Boost Your Productivity!Translate documents (Ms-Word, Ms-Excel, ...) faster and better thanks to artificial intelligence!
https://pro.wordscope.com
https://blog. wordscope .com
ELEC power control panel assembly
Elec power control panel assembly
Electrically-powered control valve
Electronic AC power controller
Electronic DC power controller
Electronic a.c.power controller
Electronic alternating current power controller
Electronic d.c.power controller
Electronic direct current power controller
Hydraulic brake control valve
Hydraulic control valve
Power brake control valve
Power control panel
Power control valve
Sander control valve
Sander valve
Sanding control valve
Sanding valve

Traduction de «power control valve » (Anglais → Français) :

TERMINOLOGIE
voir aussi les traductions en contexte ci-dessous
hydraulic control valve | power control valve

robinet de commande hydraulique


hydraulic control valve [ power control valve ]

robinet de commande hydraulique


electrically-powered control valve

électrovalve de commande


electrically-powered control valve

électrovalve de commande


hydraulic brake control valve | power brake control valve

répartiteur de freinage hydraulique


hydraulic brake control valve [ power brake control valve ]

répartiteur de freinage hydraulique


sander control valve | sander valve | sanding control valve | sanding valve

robinet de sablage | vanne electromagnétique de sablage


electronic a.c.power controller | electronic AC power controller | electronic alternating current power controller

régleur électronique de puissance à courant alternatif


electronic d.c.power controller | electronic DC power controller | electronic direct current power controller

régleur électronique de puissance à courant continu


power control panel | elec power control panel assembly | ELEC power control panel assembly

tableau de commande ELEC | tableau de commande électrique
TRADUCTIONS EN CONTEXTE
(6) All power-operated sea inlets, discharge valves and ballast tank isolating valves on a floating platform shall be designed to close automatically on loss of control power and remain closed when power is re-established until specific action is taken to open them.

(6) Les prises d’eau de mer, les vannes de décharge et les clapets d’arrêt à commande des réservoirs de lestage de la plate-forme flottante qui fonctionnent à l’électricité doivent être conçus pour se fermer automatiquement en cas de coupure du courant de commande et demeurer fermés lorsque le courant est rétabli jusqu’à ce que des mesures spécifiques soient prises pour les rouvrir.


(7) Every inlet or discharge port on a floating platform that is submerged at maximum operating draught shall be fitted with a valve that is remotely controlled from the ballast control station, and each such valve shall close automatically when the source of power fails, unless safety considerations require that it remain open.

(7) Tous les orifices d’entrée et de sortie de la plate-forme flottante qui est submergée au tirant d’eau d’exploitation maximal doivent être munis d’une vanne télécommandée du poste de commande du lest, et la vanne doit se fermer automatiquement en cas de coupure de la source d’énergie à moins que, par mesure de sécurité, elle ne doive demeurer ouverte.


(4) In every Class B ship over 22.9 m in length carrying more than 12 passengers, at least one of the power fire pumps shall be fitted with an automatic control whereby full pressure will be maintained on the fire mains at all times while passengers are on board excepting that where piping is liable to frost damage such piping may be maintained in a drained condition provided the shut-off valve and drainage cocks are located in a r ...[+++]

(4) Sur tout navire de la classe B long de plus de 22,9 m et transportant plus de 12 passagers, au moins l’une des pompes d’incendie mécaniques aura une commande automatique permettant de maintenir en tout temps la pression dans les collecteurs pendant que des passagers seront à bord, mais si le gel risque d’endommager certains tronçons des conduites, ces tronçons peuvent être vidangés et demeurer dans cet état, à condition que la soupape d’arrêt et les robinets de vidange soient situés en un endroit facilement accessible et qu’un man ...[+++]


It has six main product lines, namely control valves, natural gas solutions, pressure relief and safety valves, measurement systems, compression and power systems, and air and gas handling.

Ses six lignes de produits principales sont les vannes de régulation, les installations au gaz naturel, les limiteurs de pression et soupapes de sécurité, les systèmes de mesure, les systèmes de compression et d’alimentation et les dispositifs de traitement de l’air et des gaz.


For more results, go to https://pro.wordscope.com to translate your documents with Wordscope Pro!
The Commission's investigations focused on areas of overlap or potential overlap, notably in relation to the supply of control valves, sensors, power systems, and servos, and the supply of certain automotive components.

L'enquête investigations de la Commission s'est concentrée sur les secteurs avec un chevauchement notamment par rapport à l'approvisionnement en soupapes de commande, des sondes, des circuits électriques et servo, et l'approvisionnement en certaines pièces d'automobile.


In all cases the rpm speed of the compressor shall be that obtained when the engine is running at the speed corresponding to its maximum power or at the speed allowed by the control valve.

Dans tous les cas, le régime de rotation du compresseur est celui obtenu quand le moteur tourne à la vitesse correspondant à sa puissance maximale ou à la vitesse permise par le régulateur.


w