Boost Your Productivity!Translate documents (Ms-Word, Ms-Excel, ...) faster and better thanks to artificial intelligence!
https://pro.wordscope.com
https://blog. wordscope .com
BUV
BUV instrument
Backscatter ultraviolet instrument
Backscattered solar ultraviolet radiation instrument
Backscattered ultraviolet instrument
Backscattered ultraviolet radiation instrument
Biologically active ultraviolet radiation
Biologically effective ultraviolet radiation
Fluorescent tubes
Long-wave ultraviolet radiation
Long-wavelength ultraviolet radiation
Middle ultraviolet radiation
SBUV
SBUV instrument
Solar backscatter ultraviolet instrument
Straight fluorescent lamps
UPS
UV fluorescence
UV fluorescence photograph
UV fluorescent photograph
UV-A
UV-A radiation
UV-B
UV-B radiation
UVA
UVA radiation
UVB
UVB radiation
UVF
Ultraviolet A
Ultraviolet A radiation
Ultraviolet B
Ultraviolet B radiation
Ultraviolet fluorescence
Ultraviolet fluorescence method
Ultraviolet fluorescence microscope
Ultraviolet fluorescence photograph
Ultraviolet fluorescent properties of the paper
Ultraviolet photoelectron spectrometry
Ultraviolet photoelectron spectroscopy
Ultraviolet photoemission spectrometry
Ultraviolet photoemission spectroscopy

Traduction de «ultraviolet fluorescence » (Anglais → Français) :

TERMINOLOGIE
voir aussi les traductions en contexte ci-dessous
ultraviolet fluorescence photograph [ UV fluorescence photograph | UV fluorescent photograph ]

photographie de fluorescence d'ultraviolet [ photographie par fluorescence d'ultraviolet ]


ultraviolet fluorescence | UV fluorescence | UVF [Abbr.]

fluorescence UV


ultraviolet fluorescence method

méthode de fluorescence en lumière ultra-violette


ultraviolet fluorescence microscope

microscope à fluorescence ultraviolette


ultraviolet fluorescent properties of the paper

propriétés du papier en présence de fluorescence-ultraviolet


backscatter ultraviolet instrument | backscattered solar ultraviolet radiation instrument | backscattered ultraviolet instrument | backscattered ultraviolet radiation instrument | BUV instrument | SBUV instrument | solar backscatter ultraviolet instrument | BUV [Abbr.] | SBUV [Abbr.]

détecteur de rayonnement rétrodiffusé | détecteur de rayonnement solaire rétrodiffusé | détecteur de rayonnement ultraviolet | détecteur d'ultraviolet


ultraviolet B radiation | ultraviolet B | UVB | UV-B | UVB radiation | UV-B radiation | middle ultraviolet radiation | biologically effective ultraviolet radiation | biologically active ultraviolet radiation

rayonnement ultraviolet B | rayons ultraviolets B | ultraviolets B | UVB | UV-B | rayonnement ultraviolet moyen | ultraviolets moyens | rayons UVB | rayons UV-B


ultraviolet A radiation | ultraviolet A | UVA | UV-A | UVA radiation | UV-A radiation | long-wavelength ultraviolet radiation | long-wave ultraviolet radiation

rayonnement ultraviolet A | rayons ultraviolets A | ultraviolets A | UVA | UV-A | rayons UVA | rayons UV-A | ultraviolets longs


ultraviolet photoelectron spectroscopy | UPS | ultraviolet photoemission spectroscopy | ultraviolet photoelectron spectrometry | ultraviolet photoemission spectrometry

spectroscopie de photoélectrons UV | spectroscopie de photoémission UV | spectroscopie photoélectronique UV | spectroscopie UPS | spectrométrie de photoélectrons UV | spectrométrie de photoémission UV | spectrométrie photoélectronique UV | spectrométrie UPS


straight fluorescent lamps (1) | fluorescent tubes (2)

tubes fluorescents
TRADUCTIONS EN CONTEXTE
Fluorescent lamps without integrated ballast: discharge lamps of the low-pressure mercury type in which most of the light is emitted through the excitement of the molecules of one or more layers of phosphors by ultraviolet radiation from the discharge.

Lampes fluorescentes sans ballast intégré: lampes à vapeur de mercure à basse pression dans lesquelles la plus grande partie de la lumière est émise grâce à l’excitation des molécules d’une ou de plusieurs couches de substances luminescentes par le rayonnement ultraviolet de la décharge.


(b) after December 31, 2003, the American Society for Testing and Materials method D 5453-00, Standard Test Method for Determination of Total Sulphur in Light Hydrocarbons, Motor Fuels and Oils by Ultraviolet Fluorescence.

b) après le 31 décembre 2003, conformément à la méthode D 5453-00 de l’American Society for Testing and Materials, intitulée Standard Test Method for Determination of Total Sulfur in Light Hydrocarbons, Motor Fuels and Oils by Ultraviolet Fluorescence.


(ii) after December 31, 2003, in accordance with the American Society for Testing and Materials method D 5453-00, Standard Test Method for Determination of Total Sulfur in Light Hydrocarbons, Motor Fuels and Oils by Ultraviolet Fluorescence;

(ii) après le 31 décembre 2003, selon la méthode D 5453-00 de l’American Society for Testing and Materials, intitulée Standard Test Method for Determination of Total Sulfur in Light Hydrocarbons, Motor Fuels and Oils by Ultraviolet Fluorescence;


4. The concentration of sulphur in diesel fuel referred to in section 3 shall be measured in accordance with the ASTM International method ASTM D5453-09, Standard Test Method for Determination of Total Sulfur in Light Hydrocarbons, Spark Ignition Engine Fuel, Diesel Engine Fuel, and Engine Oil by Ultraviolet Fluorescence.

4. La concentration de soufre dans le carburant diesel prévue à l’article 3 est mesurée conformément à la méthode ASTM D5453-09 de l’ASTM International, intitulée Standard Test Method for Determination of Total Sulfur in Light Hydrocarbons, Spark Ignition Engine Fuel, Diesel Engine Fuel, and Engine Oil by Ultraviolet Fluorescence.


For more results, go to https://pro.wordscope.com to translate your documents with Wordscope Pro!
(10) The concentration of sulphur in oxygenates referred to in the definition “commercially pure oxygenate” in subsection 1(1) must be measured in accordance with the American Society for Testing and Materials method D 5453-00, Standard Test Method for Determination of Total Sulphur in Light Hydrocarbons, Motor Fuels and Oils by Ultraviolet Fluorescence.

(10) La concentration de soufre dans les produits oxygénés visée à la définition de « produit oxygéné pur de qualité commerciale » au paragraphe 1(1) doit être mesurée conformément à la méthode D 5453-00 de l’American Society for Testing and Materials, intitulée Standard Test Method for Determination of Total Sulfur in Light Hydrocarbons, Motor Fuels and Oils by Ultraviolet Fluorescence.


(11) The concentration of sulphur in butane referred to in the definition “commercially pure butane” in subsection 1(1) must be measured in accordance with the American Society for Testing and Materials method D 6667-01, Standard Test Method for Determination of Total Volatile Sulphur in Gaseous Hydrocarbons and Liquefied Petroleum Gases by Ultraviolet Fluorescence.

(11) La concentration de soufre dans le butane visée à la définition de « butane pur de qualité commerciale » au paragraphe 1(1) doit être mesurée conformément à la méthode D 6667-01 de l’American Society for Testing and Materials, intitulée Standard Test Method for Determination of Total Volatile Sulfur in Gaseous Hydrocarbons and Liquefied Petroleum Gases by Ultraviolet Fluorescence.


The reference method for the measurement of sulphur dioxide is that described in EN 14212:2005 ‘Ambient air quality — Standard method for the measurement of the concentration of sulphur dioxide by ultraviolet fluorescence’.

La méthode de référence utilisée pour la mesure de l’anhydride sulfureux est celle décrite dans la norme EN 14212 (2005): «Qualité de l’air ambiant — méthode normalisée pour le mesurage de la concentration en dioxyde de soufre par fluorescence UV».


—ultraviolet fluorescent ink, visible and transparent,

encre ultraviolette fluorescente, visible et transparente,


ultraviolet fluorescent ink, visible and transparent,

encre ultraviolette fluorescente, visible et transparente,


The reference method for the measurement of sulphur dioxide is that described in EN 14212:2005 "Ambient air quality – Standard method for the measurement of sulphur dioxide by ultraviolet fluorescence".

La méthode de référence utilisée pour la mesure de l'anhydride sulfureux est celle décrite dans la norme EN 14212 (2005): Qualité de l'air ambiant – Méthode normalisée pour le mesurage de la concentration en dioxyde de soufre par fluorescence UV.


w