Boost Your Productivity!Translate documents (Ms-Word, Ms-Excel, ...) faster and better thanks to artificial intelligence!
https://pro.wordscope.com
https://blog. wordscope .com
Calibrate waste incinerator
Calibrating waste incinerator
Controlling waste incinerator
Domestic waste incineration plant
Household refuse incineration plant
Incineration
Incineration control
MWC
MWI
Maintain waste incinerator
Maintaining waste incinerator
Municipal incinerator
Municipal waste combustor
Municipal waste incineration plant
Municipal waste-incineration plant
Operate waste incinerator
Repairing waste incinerator
Tend waste incinerator
Tending waste incinerator
Waste combustion
Waste incineration
Waste incineration plant
Waste incinerator
Waste incinerator controlling
Waste incinerator maintaining
Waste incinerator operating

Translation of "waste incinerator controlling " (English → French) :

TERMINOLOGY
see also In-Context Translations below
calibrating waste incinerator | controlling waste incinerator | calibrate waste incinerator | waste incinerator controlling

étalonner un incinérateur de déchets


maintaining waste incinerator | waste incinerator maintaining | maintain waste incinerator | repairing waste incinerator

entretenir un incinérateur de déchets


tend waste incinerator | waste incinerator operating | operate waste incinerator | tending waste incinerator

faire fonctionner un incinérateur de déchets


waste incineration plant | waste incinerator

incinérateur de déchets | installation d'incinération des déchets


municipal waste incineration plant | municipal incinerator | municipal waste combustor [ MWI | MWC ]

usine d'incinération des ordures ménagères | installation d'incinération des déchets urbains [ UIOM ]


waste incineration (1) | incineration (2) | waste combustion (3)

incinération des déchets


domestic waste incineration plant [ household refuse incineration plant ]

usine d'incinération d'ordures ménagères


municipal waste-incineration plant

installation d'incinération des déchets municipaux




IN-CONTEXT TRANSLATIONS
This can result from illegal incineration of waste, or from the use of biomass boilers without adequate combustion control and pollution prevention.

Cette pollution peut résulter de l’incinération illégale de déchets, ou de l’utilisation de chaudières à biomasse sans mesures adéquates de maîtrise de la combustion et de prévention de la pollution.


Co-incineration of waste – either as a recovery or disposal operation – is subject to similar conditions regarding approval and operation to those regarding waste incineration, in particular as to air emission limit values, waste water and residue discharge, control and monitoring and measurement requirements.

La coïncinération des déchets – qui consiste soit en une revalorisation, soit en une élimination – est soumise aux mêmes conditions d’agrément et de fonctionnement que celles concernant l’incinération, notamment en ce qui concerne les valeurs limites des émissions dans l’air, le rejet des eaux usées et des résidus, et les exigences en matière de contrôle, de surveillance et de mesures.


Co-incineration of waste – either as a recovery or disposal operation – is subject to similar conditions regarding approval and operation to those regarding waste incineration, in particular as to air emission limit values, waste water and residue discharge, control and monitoring and measurement requirements.

La coïncinération des déchets – qui consiste soit en une revalorisation, soit en une élimination – est soumise aux mêmes conditions d’agrément et de fonctionnement que celles concernant l’incinération, notamment en ce qui concerne les valeurs limites des émissions dans l’air, le rejet des eaux usées et des résidus, et les exigences en matière de contrôle, de surveillance et de mesures.


For the purposes of this Chapter waste incineration plants and waste co-incineration plants shall include all incineration lines or co-incineration lines, waste reception, storage, on site pretreatment facilities, waste-fuel and air-supply systems, boiler, facilities for the treatment of waste gases, on-site facilities for treatment or storage of residues and waste water, stack, devices and systems for controlling incineration or co-incineration operations, recording and m ...[+++]

Aux fins du présent chapitre, les installations d'incinération des déchets et les installations de coïncinération des déchets comprennent toutes les lignes d'incinération ou de coïncinération, les installations de réception, de stockage et de prétraitement sur place les systèmes d'alimentation en déchets, en combustible et en air; la chaudière, les installations de traitement des gaz résiduaires, les installations de traitement ou de stockage sur place des résidus et des eaux usées, la cheminée, les appareils et systèmes de commande des opérations d'incinération ou de coïncinération, d'enregistrement et de surveillance des conditions d' ...[+++]


For more results, go to https://pro.wordscope.com to translate your documents with Wordscope Pro!
2. Waste incineration plants and waste co-incineration plants shall be designed, equipped, built and operated in such a way that the gas resulting from the incineration or co-incineration of waste is raised, after the last injection of combustion air, in a controlled and homogeneous fashion and even under the most unfavourable conditions, to a temperature of at least 850 °C for at least two seconds.

2. Les installations d'incinération des déchets et les installations de coïncinération des déchets sont conçues, équipées, construites et exploitées de manière à ce que, même dans les conditions les plus défavorables, les gaz résultant de l'incinération ou de la coïncinération des déchets soient portés, après la dernière injection d'air de combustion, d'une façon contrôlée et homogène, à une température de 850 °C au minimum pendant au moins deux secondes.


1. Waste gases from waste incineration plants and waste co-incineration plants shall be discharged in a controlled way by means of a stack the height of which is calculated in such a way as to safeguard human health and the environment.

1. Les gaz résiduaires des installations d'incinération des déchets et des installations de coïncinération des déchets sont rejetés de manière contrôlée, par une cheminée dont la hauteur est calculée de façon à préserver la santé des personnes et l'environnement.


The Commissions proposal to reclassify municipal waste incinerators based on their energy efficiency does not recognise that installations dedicated to handling mixed wastes with a variable and unpredictable composition should be primarily concerned with the proper environmental treatment (mineralisation) of that waste and controlling emissions. Energy (and heat) recuperation should remain a secondary consideration.

La proposition de la Commission relative à la reclassification des incinérateurs de déchets en fonction de leur efficacité énergétique ne reconnaît pas que les installations destinées au traitement de déchets mélangés de composition variable et imprévisible doivent avoir pour finalité primordiale un traitement des déchets et un contrôle des émissions appropriés à l’environnement. La récupération d'énergie (et de chaleur) doit rester un aspect secondair ...[+++]


Some waste incinerators gave rise to toxic emissions (esp. dioxins/furans and heavy metals) and some landfills were not well controlled.

Certains incinérateurs produisaient des émissions toxiques (en particulier des dioxines/furanes et des métaux lourds) et certaines décharges n'étaient pas correctement contrôlées.


(9) Council Directive 96/61/EC of 24 September 1996 concerning integrated pollution prevention and control(11), Directive 2001/80/EC of the European Parliament and of the Council of 23 October 2001 on the limitation of emissions of certain pollutants into the air from large combustion plants(12) and Directive 2000/76/EC of the European Parliament and of the Council of 4 December 2000 on the incineration of waste(13) highlight the need to evaluate the potential for cogeneration in new installations.

(9) La directive 96/61/CE du Conseil du 24 septembre 1996 relative à la prévention et à la réduction intégrées de la pollution(11), la directive 2001/80/CE du Parlement européen et du Conseil du 23 octobre 2001 relative à la limitation des émissions de certains polluants dans l'atmosphère en provenance des grandes installations de combustion(12) et la directive 2000/76/CE du Parlement européen et du Conseil du 4 décembre 2000 sur l'incinération des déchets(13) soulignent la nécessité d'évaluer les potentiels de cogénération dans de nouvelles installations.


Although the common position places firm controls on permitted emissions from waste incinerators, I know that whenever proposals to build such an incinerator are made in my country, people rise in protest, they distrust the operator's claims and I have a degree of sympathy with them.

Bien que la position commune établisse des contrôles stricts sur les émissions autorisées émanant d'incinérateurs de déchets, je sais que, dans mon pays, chaque fois qu'on avance une proposition en vue de construire ce genre d'incinérateur, cela provoque une levée de boucliers, on se méfie des déclarations des opérateurs et , d'une certaine manière, je comprends cette attitude.


w