Boost Your Productivity!Translate documents (Ms-Word, Ms-Excel, ...) faster and better thanks to artificial intelligence!
https://pro.wordscope.com
https://blog. wordscope .com
Accounts receivable collection period
Average collection period
Average collection period of accounts receivable
Average collection period of receivables
Büchner flask with olive
Calibrated flask
Cask
Coffin
Collection period
Collection period of receivables
Days receiv
Days' sales in receivables
Dental flask
Erlenmeyer flask for filter pump
Fiber-optic receiver
Filter flask with olive
Flask
Graduated flask
Graduated receiving flask
Light receiver
Measuring flask
Nuclear flask
Number of days' sales in accounts receivable
Optical receiver
Optoelectronic receiver
Photo receiver
Photo-receiver
Receive fiber optic terminal device
Receive fibre optic terminal device
Receiving flask
Shipping flask
Slip-flask
Snap flask
Tight-flask
Transport cask
Transport flask
Transportation flask
Volumetric flask

Traduction de «Receiving flask » (Anglais → Français) :

TERMINOLOGIE
voir aussi les traductions en contexte ci-dessous




calibrated flask | graduated flask | measuring flask | volumetric flask

ballon gradué | ballon jaugé | carafe jaugée | fiole jaugée | flacon jaugé


cask [ flask | transportation flask | transport cask | transport flask | shipping flask | coffin | nuclear flask ]

château de transport


Erlenmeyer flask for filter pump | filter flask with olive | Büchner flask with olive

fiole Erlenmeyer pour trompes à vide | fiole d'Erlenmeyer pour trompes à vide | fiole à filtrer avec olive | fiole à filtration sous vide avec olive | fiole à filtrer à olive


snap flask [ slip-flask | tight-flask ]

châssis démotteur


optical receiver | optoelectronic receiver | photo receiver | photo-receiver | light receiver | fiber-optic receiver | receive fiber optic terminal device | receive fibre optic terminal device

récepteur optique | récepteur de lumière | récepteur à fibre optique | récepteur pour transmission par fibre optique | équipement optoélectronique de réception | récepteur optoélectronique


graduated flask | volumetric flask

fiole jaugée | fiole jaugée à un trait


collection period of receivables [ average collection period | average collection period of receivables | average collection period of accounts receivable | number of days' sales in accounts receivable | days' sales in receivables | accounts receivable collection period | collection period | days receiv ]

délai moyen de règlement des comptes clients [ délai moyen de règlement des clients | période de recouvrement des comptes clients | jours de crédit clients | période moyenne de recouvrement des créances | délai moyen de recouvrement des créances | délai moyen de recouvrement | ratio de rotation des créances clien ]


TRADUCTIONS EN CONTEXTE
When the distillation is complete, disconnect the receiving flask from the apparatus, carefully wash the extension tube and bubble trap, collecting the rinsings in the titration flask.

La distillation terminée, on détache de l'appareil le vase où l'on a recueilli le distillat, on lave soigneusement l'allonge et le barboteur en faisant couler le liquide dans le vase de titration.


5.1. Distillation apparatus consisting of a round-bottomed flask of suitable capacity, connected to a condenser by a distilling tube with a splash head, equipped, in addition, with a bubble trap on the receiving flask to prevent any loss of ammonia.

5.1. Appareil de distillation consistant en un ballon de capacité convenable, à fond rond, relié à un réfrigérant au moyen d'une boule à distiller avec chicane efficace contre l'entraînement de liquide et muni, en plus, sur le vase où l'on recueille le distillat, d'un barboteur à eau pour empêcher d'éventuelles pertes d'ammoniac.


After cooling, dilute with 50 ml of water and cool further; place this liquid in the bubbler B via filter E; next add 40 to 50 ml of 30 % sodium hydroxide, to obtain full alkalinization of the liquid and drive off the ammonia with the steam, collecting the distillate in 5 ml of boric acid solution placed in advance in the conical receiver flask with 10 ml of water, with the end of the bulb immersed in the liquid.

Après refroidissement, diluer avec 50 ml d'eau et refroidir; introduire ce liquide dans le barboteur B par l'entonnoir E; ajouter ensuite 40 à 50 ml de lessive de soude à 30 %, de manière à obtenir l'alcalinisation franche du liquide et entraîner l'ammoniac par la vapeur en recueillant le distillat dans 5 ml de solution d'acide borique placés préalablement dans la fiole conique réceptrice avec 10 ml d'eau, l'extrémité de l'ampoule plongeant dans le liquide.


After cooling, dilute with 50 ml of water and cool further; place this liquid in the bubbler B via filter E; next add 40 to 50 ml of 30 % sodium hydroxide, to obtain full alkalinization of the liquid and drive off the ammonia with the steam, collecting the distillate in 5 ml of boric acid solution placed in advance in the conical receiver flask with 10 ml of water, with the end of the bulb immersed in the liquid.

Après refroidissement, diluer avec 50 ml d'eau et refroidir; introduire ce liquide dans le barboteur B par l'entonnoir E; ajouter ensuite 40 à 50 ml de lessive de soude à 30 %, de manière à obtenir l'alcalinisation franche du liquide et entraîner l'ammoniac par la vapeur en recueillant le distillat dans 5 ml de solution d'acide borique placés préalablement dans la fiole conique réceptrice avec 10 ml d'eau, l'extrémité de l'ampoule plongeant dans le liquide.


For more results, go to https://pro.wordscope.com to translate your documents with Wordscope Pro!
3.1.1. Distillation apparatus, consisting of:- a round-bottomed 1-litre flask with ground-glass joints,- a rectifying column about 20 cm in height or any apparatus to prevent splashing,- a source of heat; any pyrolysis of extracted matter must be prevented by a suitable arrangement,- a condenser terminated by a drawn-out tube taking the distillate to the bottom of a graduated receiving flask containing several ml of water.

3.1.1. Appareil de distillation comportant:- un ballon d'un litre de capacité, à rodage normalisé,- une colonne rectificatrice de 20 cm de hauteur environ ou tout dispositif destiné à empêcher le primage,- une source de chaleur: toute pyrogénation des matières extractives doit être évitée par un dispositif approprié,- un réfrigérant terminé par un tube effilé conduisant le distillat dans le fond de la fiole jaugée réceptrice contenant quelques millilitres d'eau.


Place 5 ml of sodium hydroxide solution (3.2.6) into the receiver flask.

Dans le ballon récepteur placer 5 ml de solution d'hydroxyde de sodium (3.2.6).


w